mirror of
				https://github.com/torvalds/linux.git
				synced 2025-11-04 10:40:15 +02:00 
			
		
		
		
	scsi: docs: convert BusLogic.txt to ReST
Link: https://lore.kernel.org/r/750629b6a5233c85c5391c44d126606b8aabefc8.1583136624.git.mchehab+huawei@kernel.org Acked-by: Khalid Aziz <khalid@gonehiking.org> Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
		
							parent
							
								
									1d4f8dfe2d
								
							
						
					
					
						commit
						977b899ce3
					
				
					 4 changed files with 67 additions and 27 deletions
				
			
		| 
						 | 
					@ -1,6 +1,11 @@
 | 
				
			||||||
 | 
					.. SPDX-License-Identifier: GPL-2.0
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					=========================================================
 | 
				
			||||||
BusLogic MultiMaster and FlashPoint SCSI Driver for Linux
 | 
					BusLogic MultiMaster and FlashPoint SCSI Driver for Linux
 | 
				
			||||||
 | 
					=========================================================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			 Version 2.0.15 for Linux 2.0
 | 
								 Version 2.0.15 for Linux 2.0
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			 Version 2.1.15 for Linux 2.1
 | 
								 Version 2.1.15 for Linux 2.1
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			      PRODUCTION RELEASE
 | 
								      PRODUCTION RELEASE
 | 
				
			||||||
| 
						 | 
					@ -8,13 +13,16 @@
 | 
				
			||||||
				17 August 1998
 | 
									17 August 1998
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			       Leonard N. Zubkoff
 | 
								       Leonard N. Zubkoff
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			       Dandelion Digital
 | 
								       Dandelion Digital
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			       lnz@dandelion.com
 | 
								       lnz@dandelion.com
 | 
				
			||||||
 | 
					
 | 
				
			||||||
	 Copyright 1995-1998 by Leonard N. Zubkoff <lnz@dandelion.com>
 | 
						 Copyright 1995-1998 by Leonard N. Zubkoff <lnz@dandelion.com>
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
				 INTRODUCTION
 | 
					Introduction
 | 
				
			||||||
 | 
					============
 | 
				
			||||||
 | 
					
 | 
				
			||||||
BusLogic, Inc. designed and manufactured a variety of high performance SCSI
 | 
					BusLogic, Inc. designed and manufactured a variety of high performance SCSI
 | 
				
			||||||
host adapters which share a common programming interface across a diverse
 | 
					host adapters which share a common programming interface across a diverse
 | 
				
			||||||
| 
						 | 
					@ -86,9 +94,11 @@ Contact information for offices in Europe and Japan is available on the Web
 | 
				
			||||||
site.
 | 
					site.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
				DRIVER FEATURES
 | 
					Driver Features
 | 
				
			||||||
 | 
					===============
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o Configuration Reporting and Testing
 | 
					Configuration Reporting and Testing
 | 
				
			||||||
 | 
					-----------------------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  During system initialization, the driver reports extensively on the host
 | 
					  During system initialization, the driver reports extensively on the host
 | 
				
			||||||
  adapter hardware configuration, including the synchronous transfer parameters
 | 
					  adapter hardware configuration, including the synchronous transfer parameters
 | 
				
			||||||
| 
						 | 
					@ -130,7 +140,8 @@ o Configuration Reporting and Testing
 | 
				
			||||||
    The status of Wide Negotiation, Disconnect/Reconnect, and Tagged Queuing
 | 
					    The status of Wide Negotiation, Disconnect/Reconnect, and Tagged Queuing
 | 
				
			||||||
    are reported as "Enabled", Disabled", or a sequence of "Y" and "N" letters.
 | 
					    are reported as "Enabled", Disabled", or a sequence of "Y" and "N" letters.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o Performance Features
 | 
					Performance Features
 | 
				
			||||||
 | 
					--------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  BusLogic SCSI Host Adapters directly implement SCSI-2 Tagged Queuing, and so
 | 
					  BusLogic SCSI Host Adapters directly implement SCSI-2 Tagged Queuing, and so
 | 
				
			||||||
  support has been included in the driver to utilize tagged queuing with any
 | 
					  support has been included in the driver to utilize tagged queuing with any
 | 
				
			||||||
| 
						 | 
					@ -150,7 +161,8 @@ o Performance Features
 | 
				
			||||||
  queue depth of 1 is selected.  Tagged queuing is also disabled for individual
 | 
					  queue depth of 1 is selected.  Tagged queuing is also disabled for individual
 | 
				
			||||||
  target devices if disconnect/reconnect is disabled for that device.
 | 
					  target devices if disconnect/reconnect is disabled for that device.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o Robustness Features
 | 
					Robustness Features
 | 
				
			||||||
 | 
					-------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  The driver implements extensive error recovery procedures.  When the higher
 | 
					  The driver implements extensive error recovery procedures.  When the higher
 | 
				
			||||||
  level parts of the SCSI subsystem request that a timed out command be reset,
 | 
					  level parts of the SCSI subsystem request that a timed out command be reset,
 | 
				
			||||||
| 
						 | 
					@ -174,7 +186,8 @@ o Robustness Features
 | 
				
			||||||
  lock up or crash, and thereby allowing a clean shutdown and restart after the
 | 
					  lock up or crash, and thereby allowing a clean shutdown and restart after the
 | 
				
			||||||
  offending component is removed.
 | 
					  offending component is removed.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o PCI Configuration Support
 | 
					PCI Configuration Support
 | 
				
			||||||
 | 
					-------------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  On PCI systems running kernels compiled with PCI BIOS support enabled, this
 | 
					  On PCI systems running kernels compiled with PCI BIOS support enabled, this
 | 
				
			||||||
  driver will interrogate the PCI configuration space and use the I/O port
 | 
					  driver will interrogate the PCI configuration space and use the I/O port
 | 
				
			||||||
| 
						 | 
					@ -184,19 +197,22 @@ o PCI Configuration Support
 | 
				
			||||||
  used to disable the ISA compatible I/O port entirely as it is not necessary.
 | 
					  used to disable the ISA compatible I/O port entirely as it is not necessary.
 | 
				
			||||||
  The ISA compatible I/O port is disabled by default on the BT-948/958/958D.
 | 
					  The ISA compatible I/O port is disabled by default on the BT-948/958/958D.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o /proc File System Support
 | 
					/proc File System Support
 | 
				
			||||||
 | 
					-------------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  Copies of the host adapter configuration information together with updated
 | 
					  Copies of the host adapter configuration information together with updated
 | 
				
			||||||
  data transfer and error recovery statistics are available through the
 | 
					  data transfer and error recovery statistics are available through the
 | 
				
			||||||
  /proc/scsi/BusLogic/<N> interface.
 | 
					  /proc/scsi/BusLogic/<N> interface.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o Shared Interrupts Support
 | 
					Shared Interrupts Support
 | 
				
			||||||
 | 
					-------------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  On systems that support shared interrupts, any number of BusLogic Host
 | 
					  On systems that support shared interrupts, any number of BusLogic Host
 | 
				
			||||||
  Adapters may share the same interrupt request channel.
 | 
					  Adapters may share the same interrupt request channel.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			    SUPPORTED HOST ADAPTERS
 | 
					Supported Host Adapters
 | 
				
			||||||
 | 
					=======================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
The following list comprises the supported BusLogic SCSI Host Adapters as of
 | 
					The following list comprises the supported BusLogic SCSI Host Adapters as of
 | 
				
			||||||
the date of this document.  It is recommended that anyone purchasing a BusLogic
 | 
					the date of this document.  It is recommended that anyone purchasing a BusLogic
 | 
				
			||||||
| 
						 | 
					@ -205,6 +221,7 @@ that it is or will be supported.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
FlashPoint Series PCI Host Adapters:
 | 
					FlashPoint Series PCI Host Adapters:
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					=======================	=============================================
 | 
				
			||||||
FlashPoint LT (BT-930)	Ultra SCSI-3
 | 
					FlashPoint LT (BT-930)	Ultra SCSI-3
 | 
				
			||||||
FlashPoint LT (BT-930R)	Ultra SCSI-3 with RAIDPlus
 | 
					FlashPoint LT (BT-930R)	Ultra SCSI-3 with RAIDPlus
 | 
				
			||||||
FlashPoint LT (BT-920)	Ultra SCSI-3 (BT-930 without BIOS)
 | 
					FlashPoint LT (BT-920)	Ultra SCSI-3 (BT-930 without BIOS)
 | 
				
			||||||
| 
						 | 
					@ -214,15 +231,19 @@ FlashPoint LW (BT-950)	Wide Ultra SCSI-3
 | 
				
			||||||
FlashPoint LW (BT-950R)	Wide Ultra SCSI-3 with RAIDPlus
 | 
					FlashPoint LW (BT-950R)	Wide Ultra SCSI-3 with RAIDPlus
 | 
				
			||||||
FlashPoint DW (BT-952)	Dual Channel Wide Ultra SCSI-3
 | 
					FlashPoint DW (BT-952)	Dual Channel Wide Ultra SCSI-3
 | 
				
			||||||
FlashPoint DW (BT-952R)	Dual Channel Wide Ultra SCSI-3 with RAIDPlus
 | 
					FlashPoint DW (BT-952R)	Dual Channel Wide Ultra SCSI-3 with RAIDPlus
 | 
				
			||||||
 | 
					=======================	=============================================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
MultiMaster "W" Series Host Adapters:
 | 
					MultiMaster "W" Series Host Adapters:
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					=======     ===		==============================
 | 
				
			||||||
BT-948	    PCI		Ultra SCSI-3
 | 
					BT-948	    PCI		Ultra SCSI-3
 | 
				
			||||||
BT-958	    PCI		Wide Ultra SCSI-3
 | 
					BT-958	    PCI		Wide Ultra SCSI-3
 | 
				
			||||||
BT-958D	    PCI		Wide Differential Ultra SCSI-3
 | 
					BT-958D	    PCI		Wide Differential Ultra SCSI-3
 | 
				
			||||||
 | 
					=======     ===		==============================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
MultiMaster "C" Series Host Adapters:
 | 
					MultiMaster "C" Series Host Adapters:
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					========    ====	==============================
 | 
				
			||||||
BT-946C	    PCI		Fast SCSI-2
 | 
					BT-946C	    PCI		Fast SCSI-2
 | 
				
			||||||
BT-956C	    PCI		Wide Fast SCSI-2
 | 
					BT-956C	    PCI		Wide Fast SCSI-2
 | 
				
			||||||
BT-956CD    PCI		Wide Differential Fast SCSI-2
 | 
					BT-956CD    PCI		Wide Differential Fast SCSI-2
 | 
				
			||||||
| 
						 | 
					@ -232,9 +253,11 @@ BT-757C	    EISA	Wide Fast SCSI-2
 | 
				
			||||||
BT-757CD    EISA	Wide Differential Fast SCSI-2
 | 
					BT-757CD    EISA	Wide Differential Fast SCSI-2
 | 
				
			||||||
BT-545C	    ISA		Fast SCSI-2
 | 
					BT-545C	    ISA		Fast SCSI-2
 | 
				
			||||||
BT-540CF    ISA		Fast SCSI-2
 | 
					BT-540CF    ISA		Fast SCSI-2
 | 
				
			||||||
 | 
					========    ====	==============================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
MultiMaster "S" Series Host Adapters:
 | 
					MultiMaster "S" Series Host Adapters:
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					=======     ====	==============================
 | 
				
			||||||
BT-445S	    VLB		Fast SCSI-2
 | 
					BT-445S	    VLB		Fast SCSI-2
 | 
				
			||||||
BT-747S	    EISA	Fast SCSI-2
 | 
					BT-747S	    EISA	Fast SCSI-2
 | 
				
			||||||
BT-747D	    EISA	Differential Fast SCSI-2
 | 
					BT-747D	    EISA	Differential Fast SCSI-2
 | 
				
			||||||
| 
						 | 
					@ -244,11 +267,14 @@ BT-545S	    ISA		Fast SCSI-2
 | 
				
			||||||
BT-542D	    ISA		Differential Fast SCSI-2
 | 
					BT-542D	    ISA		Differential Fast SCSI-2
 | 
				
			||||||
BT-742A	    EISA	SCSI-2 (742A revision H)
 | 
					BT-742A	    EISA	SCSI-2 (742A revision H)
 | 
				
			||||||
BT-542B	    ISA		SCSI-2 (542B revision H)
 | 
					BT-542B	    ISA		SCSI-2 (542B revision H)
 | 
				
			||||||
 | 
					=======     ====	==============================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
MultiMaster "A" Series Host Adapters:
 | 
					MultiMaster "A" Series Host Adapters:
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					=======     ====	==============================
 | 
				
			||||||
BT-742A	    EISA	SCSI-2 (742A revisions A - G)
 | 
					BT-742A	    EISA	SCSI-2 (742A revisions A - G)
 | 
				
			||||||
BT-542B	    ISA		SCSI-2 (542B revisions A - G)
 | 
					BT-542B	    ISA		SCSI-2 (542B revisions A - G)
 | 
				
			||||||
 | 
					=======     ====	==============================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
AMI FastDisk Host Adapters that are true BusLogic MultiMaster clones are also
 | 
					AMI FastDisk Host Adapters that are true BusLogic MultiMaster clones are also
 | 
				
			||||||
supported by this driver.
 | 
					supported by this driver.
 | 
				
			||||||
| 
						 | 
					@ -260,9 +286,11 @@ list.  The retail kit includes the bare board and manual as well as cabling and
 | 
				
			||||||
driver media and documentation that are not provided with bare boards.
 | 
					driver media and documentation that are not provided with bare boards.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			 FLASHPOINT INSTALLATION NOTES
 | 
					FlashPoint Installation Notes
 | 
				
			||||||
 | 
					=============================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o RAIDPlus Support
 | 
					RAIDPlus Support
 | 
				
			||||||
 | 
					----------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  FlashPoint Host Adapters now include RAIDPlus, Mylex's bootable software
 | 
					  FlashPoint Host Adapters now include RAIDPlus, Mylex's bootable software
 | 
				
			||||||
  RAID.  RAIDPlus is not supported on Linux, and there are no plans to support
 | 
					  RAID.  RAIDPlus is not supported on Linux, and there are no plans to support
 | 
				
			||||||
| 
						 | 
					@ -273,7 +301,8 @@ o RAIDPlus Support
 | 
				
			||||||
  than RAIDPlus, so there is little impetus to include RAIDPlus support in the
 | 
					  than RAIDPlus, so there is little impetus to include RAIDPlus support in the
 | 
				
			||||||
  BusLogic driver.
 | 
					  BusLogic driver.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o Enabling UltraSCSI Transfers
 | 
					Enabling UltraSCSI Transfers
 | 
				
			||||||
 | 
					----------------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  FlashPoint Host Adapters ship with their configuration set to "Factory
 | 
					  FlashPoint Host Adapters ship with their configuration set to "Factory
 | 
				
			||||||
  Default" settings that are conservative and do not allow for UltraSCSI speed
 | 
					  Default" settings that are conservative and do not allow for UltraSCSI speed
 | 
				
			||||||
| 
						 | 
					@ -287,12 +316,14 @@ o Enabling UltraSCSI Transfers
 | 
				
			||||||
  the "Optimum Performance" settings are loaded.
 | 
					  the "Optimum Performance" settings are loaded.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
		      BT-948/958/958D INSTALLATION NOTES
 | 
					BT-948/958/958D Installation Notes
 | 
				
			||||||
 | 
					==================================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
The BT-948/958/958D PCI Ultra SCSI Host Adapters have some features which may
 | 
					The BT-948/958/958D PCI Ultra SCSI Host Adapters have some features which may
 | 
				
			||||||
require attention in some circumstances when installing Linux.
 | 
					require attention in some circumstances when installing Linux.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o PCI I/O Port Assignments
 | 
					PCI I/O Port Assignments
 | 
				
			||||||
 | 
					------------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  When configured to factory default settings, the BT-948/958/958D will only
 | 
					  When configured to factory default settings, the BT-948/958/958D will only
 | 
				
			||||||
  recognize the PCI I/O port assignments made by the motherboard's PCI BIOS.
 | 
					  recognize the PCI I/O port assignments made by the motherboard's PCI BIOS.
 | 
				
			||||||
| 
						 | 
					@ -312,7 +343,8 @@ o PCI I/O Port Assignments
 | 
				
			||||||
  possible future I/O port conflicts.  The older BT-946C/956C/956CD also have
 | 
					  possible future I/O port conflicts.  The older BT-946C/956C/956CD also have
 | 
				
			||||||
  this configuration option, but the factory default setting is "Primary".
 | 
					  this configuration option, but the factory default setting is "Primary".
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o PCI Slot Scanning Order
 | 
					PCI Slot Scanning Order
 | 
				
			||||||
 | 
					-----------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  In systems with multiple BusLogic PCI Host Adapters, the order in which the
 | 
					  In systems with multiple BusLogic PCI Host Adapters, the order in which the
 | 
				
			||||||
  PCI slots are scanned may appear reversed with the BT-948/958/958D as
 | 
					  PCI slots are scanned may appear reversed with the BT-948/958/958D as
 | 
				
			||||||
| 
						 | 
					@ -339,7 +371,8 @@ o PCI Slot Scanning Order
 | 
				
			||||||
  so as to recognize the host adapters in the same order as they are enumerated
 | 
					  so as to recognize the host adapters in the same order as they are enumerated
 | 
				
			||||||
  by the host adapter's BIOS.
 | 
					  by the host adapter's BIOS.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
o Enabling UltraSCSI Transfers
 | 
					Enabling UltraSCSI Transfers
 | 
				
			||||||
 | 
					----------------------------
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  The BT-948/958/958D ship with their configuration set to "Factory Default"
 | 
					  The BT-948/958/958D ship with their configuration set to "Factory Default"
 | 
				
			||||||
  settings that are conservative and do not allow for UltraSCSI speed to be
 | 
					  settings that are conservative and do not allow for UltraSCSI speed to be
 | 
				
			||||||
| 
						 | 
					@ -353,7 +386,8 @@ o Enabling UltraSCSI Transfers
 | 
				
			||||||
  "Optimum Performance" settings are loaded.
 | 
					  "Optimum Performance" settings are loaded.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
				DRIVER OPTIONS
 | 
					Driver Options
 | 
				
			||||||
 | 
					==============
 | 
				
			||||||
 | 
					
 | 
				
			||||||
BusLogic Driver Options may be specified either via the Linux Kernel Command
 | 
					BusLogic Driver Options may be specified either via the Linux Kernel Command
 | 
				
			||||||
Line or via the Loadable Kernel Module Installation Facility.  Driver Options
 | 
					Line or via the Loadable Kernel Module Installation Facility.  Driver Options
 | 
				
			||||||
| 
						 | 
					@ -520,30 +554,34 @@ The following examples demonstrate setting the Queue Depth for Target Devices
 | 
				
			||||||
Devices on the second host adapter to 31, and the Bus Settle Time on the
 | 
					Devices on the second host adapter to 31, and the Bus Settle Time on the
 | 
				
			||||||
second host adapter to 30 seconds.
 | 
					second host adapter to 30 seconds.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
Linux Kernel Command Line:
 | 
					Linux Kernel Command Line::
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  linux BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30
 | 
					  linux BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30
 | 
				
			||||||
 | 
					
 | 
				
			||||||
LILO Linux Boot Loader (in /etc/lilo.conf):
 | 
					LILO Linux Boot Loader (in /etc/lilo.conf)::
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  append = "BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"
 | 
					  append = "BusLogic=QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"
 | 
				
			||||||
 | 
					
 | 
				
			||||||
INSMOD Loadable Kernel Module Installation Facility:
 | 
					INSMOD Loadable Kernel Module Installation Facility::
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  insmod BusLogic.o \
 | 
					  insmod BusLogic.o \
 | 
				
			||||||
      'BusLogic="QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"'
 | 
					      'BusLogic="QueueDepth:[,7,15];QueueDepth:31,BusSettleTime:30"'
 | 
				
			||||||
 | 
					
 | 
				
			||||||
NOTE: Module Utilities 2.1.71 or later is required for correct parsing
 | 
					
 | 
				
			||||||
 | 
					.. Note::
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					      Module Utilities 2.1.71 or later is required for correct parsing
 | 
				
			||||||
      of driver options containing commas.
 | 
					      of driver options containing commas.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
			      DRIVER INSTALLATION
 | 
					Driver Installation
 | 
				
			||||||
 | 
					===================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
This distribution was prepared for Linux kernel version 2.0.35, but should be
 | 
					This distribution was prepared for Linux kernel version 2.0.35, but should be
 | 
				
			||||||
compatible with 2.0.4 or any later 2.0 series kernel.
 | 
					compatible with 2.0.4 or any later 2.0 series kernel.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
To install the new BusLogic SCSI driver, you may use the following commands,
 | 
					To install the new BusLogic SCSI driver, you may use the following commands,
 | 
				
			||||||
replacing "/usr/src" with wherever you keep your Linux kernel source tree:
 | 
					replacing "/usr/src" with wherever you keep your Linux kernel source tree::
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  cd /usr/src
 | 
					  cd /usr/src
 | 
				
			||||||
  tar -xvzf BusLogic-2.0.15.tar.gz
 | 
					  tar -xvzf BusLogic-2.0.15.tar.gz
 | 
				
			||||||
| 
						 | 
					@ -557,7 +595,8 @@ Then install "arch/x86/boot/zImage" as your standard kernel, run lilo if
 | 
				
			||||||
appropriate, and reboot.
 | 
					appropriate, and reboot.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
 | 
					
 | 
				
			||||||
		      BUSLOGIC ANNOUNCEMENTS MAILING LIST
 | 
					BusLogic Announcements Mailing List
 | 
				
			||||||
 | 
					===================================
 | 
				
			||||||
 | 
					
 | 
				
			||||||
The BusLogic Announcements Mailing List provides a forum for informing Linux
 | 
					The BusLogic Announcements Mailing List provides a forum for informing Linux
 | 
				
			||||||
users of new driver releases and other announcements regarding Linux support
 | 
					users of new driver releases and other announcements regarding Linux support
 | 
				
			||||||
| 
						 | 
					@ -15,5 +15,6 @@ Linux SCSI Subsystem
 | 
				
			||||||
   aic7xxx
 | 
					   aic7xxx
 | 
				
			||||||
   bfa
 | 
					   bfa
 | 
				
			||||||
   bnx2fc
 | 
					   bnx2fc
 | 
				
			||||||
 | 
					   BusLogic
 | 
				
			||||||
 | 
					
 | 
				
			||||||
   scsi_transport_srp/figures
 | 
					   scsi_transport_srp/figures
 | 
				
			||||||
| 
						 | 
					
 | 
				
			||||||
| 
						 | 
					@ -3652,7 +3652,7 @@ static bool __init blogic_parse(char **str, char *keyword)
 | 
				
			||||||
  selected host adapter.
 | 
					  selected host adapter.
 | 
				
			||||||
 | 
					
 | 
				
			||||||
  The BusLogic Driver Probing Options are described in
 | 
					  The BusLogic Driver Probing Options are described in
 | 
				
			||||||
  <file:Documentation/scsi/BusLogic.txt>.
 | 
					  <file:Documentation/scsi/BusLogic.rst>.
 | 
				
			||||||
*/
 | 
					*/
 | 
				
			||||||
 | 
					
 | 
				
			||||||
static int __init blogic_parseopts(char *options)
 | 
					static int __init blogic_parseopts(char *options)
 | 
				
			||||||
| 
						 | 
					
 | 
				
			||||||
| 
						 | 
					@ -502,7 +502,7 @@ config SCSI_BUSLOGIC
 | 
				
			||||||
	  This is support for BusLogic MultiMaster and FlashPoint SCSI Host
 | 
						  This is support for BusLogic MultiMaster and FlashPoint SCSI Host
 | 
				
			||||||
	  Adapters. Consult the SCSI-HOWTO, available from
 | 
						  Adapters. Consult the SCSI-HOWTO, available from
 | 
				
			||||||
	  <http://www.tldp.org/docs.html#howto>, and the files
 | 
						  <http://www.tldp.org/docs.html#howto>, and the files
 | 
				
			||||||
	  <file:Documentation/scsi/BusLogic.txt> and
 | 
						  <file:Documentation/scsi/BusLogic.rst> and
 | 
				
			||||||
	  <file:Documentation/scsi/FlashPoint.txt> for more information.
 | 
						  <file:Documentation/scsi/FlashPoint.txt> for more information.
 | 
				
			||||||
	  Note that support for FlashPoint is only available for 32-bit
 | 
						  Note that support for FlashPoint is only available for 32-bit
 | 
				
			||||||
	  x86 configurations.
 | 
						  x86 configurations.
 | 
				
			||||||
| 
						 | 
					
 | 
				
			||||||
		Loading…
	
		Reference in a new issue