	thermal: generic-adc: make lookup table optional
Certain ADC channels, such as the xilinx-ams temperature channels, give milliCelcius already when read with iio_read_channel_processed. Rather than having to provide a 1:1 dummy lookup table, simply allow to bypass the mechanism. Signed-off-by: Jean-Francois Dagenais <jeff.dagenais@gmail.com> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
		
							parent
							
								
									f86a7a847c
								
							
						
					
					
						commit
						d36e2fa025
					
				
					 1 changed files with 6 additions and 3 deletions
				
			
		| 
						 | 
				
			
			@ -29,6 +29,9 @@ static int gadc_thermal_adc_to_temp(struct gadc_thermal_info *gti, int val)
 | 
			
		|||
	int temp, temp_hi, temp_lo, adc_hi, adc_lo;
 | 
			
		||||
	int i;
 | 
			
		||||
 | 
			
		||||
	if (!gti->lookup_table)
 | 
			
		||||
		return val;
 | 
			
		||||
 | 
			
		||||
	for (i = 0; i < gti->nlookup_table; i++) {
 | 
			
		||||
		if (val >= gti->lookup_table[2 * i + 1])
 | 
			
		||||
			break;
 | 
			
		||||
| 
						 | 
				
			
			@ -81,9 +84,9 @@ static int gadc_thermal_read_linear_lookup_table(struct device *dev,
 | 
			
		|||
 | 
			
		||||
	ntable = of_property_count_elems_of_size(np, "temperature-lookup-table",
 | 
			
		||||
						 sizeof(u32));
 | 
			
		||||
	if (ntable < 0) {
 | 
			
		||||
		dev_err(dev, "Lookup table is not provided\n");
 | 
			
		||||
		return ntable;
 | 
			
		||||
	if (ntable <= 0) {
 | 
			
		||||
		dev_notice(dev, "no lookup table, assuming DAC channel returns milliCelcius\n");
 | 
			
		||||
		return 0;
 | 
			
		||||
	}
 | 
			
		||||
 | 
			
		||||
	if (ntable % 2) {
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||
		Loading…
	