	dt-bindings: thermal: Remove "cooling-{min|max}-level" properties
The "cooling-min-level" and "cooling-max-level" properties are not parsed by any part of kernel currently and the max cooling state of a CPU cooling device is found by referring to the cpufreq table instead. Remove the unused bindings. Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org> Reviewed-by: Rob Herring <robh@kernel.org> Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
		
							parent
							
								
									8b8b5903d5
								
							
						
					
					
						commit
						e04907dbc2
					
				
					 1 changed files with 1 additions and 15 deletions
				
			
		| 
						 | 
				
			
			@ -55,8 +55,7 @@ of heat dissipation). For example a fan's cooling states correspond to
 | 
			
		|||
the different fan speeds possible. Cooling states are referred to by
 | 
			
		||||
single unsigned integers, where larger numbers mean greater heat
 | 
			
		||||
dissipation. The precise set of cooling states associated with a device
 | 
			
		||||
(as referred to by the cooling-min-level and cooling-max-level
 | 
			
		||||
properties) should be defined in a particular device's binding.
 | 
			
		||||
should be defined in a particular device's binding.
 | 
			
		||||
For more examples of cooling devices, refer to the example sections below.
 | 
			
		||||
 | 
			
		||||
Required properties:
 | 
			
		||||
| 
						 | 
				
			
			@ -69,15 +68,6 @@ Required properties:
 | 
			
		|||
			See Cooling device maps section below for more details
 | 
			
		||||
			on how consumers refer to cooling devices.
 | 
			
		||||
 | 
			
		||||
Optional properties:
 | 
			
		||||
- cooling-min-level:	An integer indicating the smallest
 | 
			
		||||
  Type: unsigned	cooling state accepted. Typically 0.
 | 
			
		||||
  Size: one cell
 | 
			
		||||
 | 
			
		||||
- cooling-max-level:	An integer indicating the largest
 | 
			
		||||
  Type: unsigned	cooling state accepted.
 | 
			
		||||
  Size: one cell
 | 
			
		||||
 | 
			
		||||
* Trip points
 | 
			
		||||
 | 
			
		||||
The trip node is a node to describe a point in the temperature domain
 | 
			
		||||
| 
						 | 
				
			
			@ -226,8 +216,6 @@ cpus {
 | 
			
		|||
			396000  950000
 | 
			
		||||
			198000  850000
 | 
			
		||||
		>;
 | 
			
		||||
		cooling-min-level = <0>;
 | 
			
		||||
		cooling-max-level = <3>;
 | 
			
		||||
		#cooling-cells = <2>; /* min followed by max */
 | 
			
		||||
	};
 | 
			
		||||
	...
 | 
			
		||||
| 
						 | 
				
			
			@ -241,8 +229,6 @@ cpus {
 | 
			
		|||
	 */
 | 
			
		||||
	fan0: fan@48 {
 | 
			
		||||
		...
 | 
			
		||||
		cooling-min-level = <0>;
 | 
			
		||||
		cooling-max-level = <9>;
 | 
			
		||||
		#cooling-cells = <2>; /* min followed by max */
 | 
			
		||||
	};
 | 
			
		||||
};
 | 
			
		||||
| 
						 | 
				
			
			
 | 
			
		|||