mirror of
				https://github.com/torvalds/linux.git
				synced 2025-11-03 18:20:25 +02:00 
			
		
		
		
	The previously used URLs are dead. Sensirion provides permalinks for their product datasheets at https://www.sensirion.com/en/about-us/links/. Signed-off-by: Danilo Bargen <mail@dbrgn.ch> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
		
			
				
	
	
		
			50 lines
		
	
	
	
		
			1.6 KiB
		
	
	
	
		
			Text
		
	
	
	
	
	
			
		
		
	
	
			50 lines
		
	
	
	
		
			1.6 KiB
		
	
	
	
		
			Text
		
	
	
	
	
	
Kernel driver sht21
 | 
						|
===================
 | 
						|
 | 
						|
Supported chips:
 | 
						|
  * Sensirion SHT21
 | 
						|
    Prefix: 'sht21'
 | 
						|
    Addresses scanned: none
 | 
						|
    Datasheet: Publicly available at the Sensirion website
 | 
						|
    http://www.sensirion.com/file/datasheet_sht21
 | 
						|
 | 
						|
  * Sensirion SHT25
 | 
						|
    Prefix: 'sht25'
 | 
						|
    Addresses scanned: none
 | 
						|
    Datasheet: Publicly available at the Sensirion website
 | 
						|
    http://www.sensirion.com/file/datasheet_sht25
 | 
						|
 | 
						|
Author:
 | 
						|
  Urs Fleisch <urs.fleisch@sensirion.com>
 | 
						|
 | 
						|
Description
 | 
						|
-----------
 | 
						|
 | 
						|
The SHT21 and SHT25 are humidity and temperature sensors in a DFN package of
 | 
						|
only 3 x 3 mm footprint and 1.1 mm height. The difference between the two
 | 
						|
devices is the higher level of precision of the SHT25 (1.8% relative humidity,
 | 
						|
0.2 degree Celsius) compared with the SHT21 (2.0% relative humidity,
 | 
						|
0.3 degree Celsius).
 | 
						|
 | 
						|
The devices communicate with the I2C protocol. All sensors are set to the same
 | 
						|
I2C address 0x40, so an entry with I2C_BOARD_INFO("sht21", 0x40) can be used
 | 
						|
in the board setup code.
 | 
						|
 | 
						|
sysfs-Interface
 | 
						|
---------------
 | 
						|
 | 
						|
temp1_input - temperature input
 | 
						|
humidity1_input - humidity input
 | 
						|
eic - Electronic Identification Code
 | 
						|
 | 
						|
Notes
 | 
						|
-----
 | 
						|
 | 
						|
The driver uses the default resolution settings of 12 bit for humidity and 14
 | 
						|
bit for temperature, which results in typical measurement times of 22 ms for
 | 
						|
humidity and 66 ms for temperature. To keep self heating below 0.1 degree
 | 
						|
Celsius, the device should not be active for more than 10% of the time,
 | 
						|
e.g. maximum two measurements per second at the given resolution.
 | 
						|
 | 
						|
Different resolutions, the on-chip heater, and using the CRC checksum
 | 
						|
are not supported yet.
 |