forked from mirrors/linux
		
	ACPI / battery: Fix warning message in acpi_battery_get_state()
capacity_now should be assigned after comparing it to design_capacity.
Otherwise warning is printed even when capacity_now before assignment is
equal to design_capacity, making the check useless and "current charge level"
wrong (it should be higher than, not equal to, "maximum charge level", which
is full_charge_capacity):
"battery: reported current charge level (56410) is higher than reported
maximum charge level (56410)."
Fixes: 232de51437 (ACPI / battery: fix wrong value of capacity_now reported when fully charged)
Signed-off-by: Mariusz Ceier <mceier+kernel@gmail.com>
Cc: 3.16+ <stable@vger.kernel.org> # 3.16+
[rjw: Subject]
Signed-off-by: Rafael J. Wysocki <rafael.j.wysocki@intel.com>
			
			
This commit is contained in:
		
							parent
							
								
									3a54a57dce
								
							
						
					
					
						commit
						d719870b41
					
				
					 1 changed files with 1 additions and 1 deletions
				
			
		|  | @ -540,12 +540,12 @@ static int acpi_battery_get_state(struct acpi_battery *battery) | |||
| 	 */ | ||||
| 	if (battery->capacity_now > battery->full_charge_capacity | ||||
| 	    && battery->full_charge_capacity != ACPI_BATTERY_VALUE_UNKNOWN) { | ||||
| 		battery->capacity_now = battery->full_charge_capacity; | ||||
| 		if (battery->capacity_now != battery->design_capacity) | ||||
| 			printk_once(KERN_WARNING FW_BUG | ||||
| 				"battery: reported current charge level (%d) " | ||||
| 				"is higher than reported maximum charge level (%d).\n", | ||||
| 				battery->capacity_now, battery->full_charge_capacity); | ||||
| 		battery->capacity_now = battery->full_charge_capacity; | ||||
| 	} | ||||
| 
 | ||||
| 	if (test_bit(ACPI_BATTERY_QUIRK_PERCENTAGE_CAPACITY, &battery->flags) | ||||
|  |  | |||